High Voltage Motor Insulation On-Line Monitoring System
High Voltage Motor Insulation On-Line Monitoring System

Related Suggestion:

  • Product introduction
  • Product features
  • Product specifications
  • Product applications

——High Voltage Motor Insulation On-Line Monitoring System——


High Voltage Motor Insulation On-Line Monitoring System

High Voltage Motor Insulation On-Line Monitoring System

High Voltage Motor Insulation On-Line Monitoring System

What benefits can the Products bring?

1. Ensure Motor starting-up safely

According to the operation regulations: Starting up High voltage Motor without testing insulation is strictly prohibited! At present now, many of the users and their maintenance person by testing the insulation frequently to know the insulation level for high voltage motors or by alternating switch between the operating Motor and standby Motor to solve this problem. In the strict sense that doesn’t fit the regulations, because during the time from last testing till the Motor starting the insulation will be changed by the climatic&environment or other factors. ZJC High voltage insulation online monitoring system can be used to test and monitor insulation of Motor at any time, so operation person could know the insulation level of the motor online so that can ensure the Motor could be start at any time in a safe and reliable way.


2. Ensure power system operation in safety

To make sure the high voltage system operation safety, all the insulation of equipment &Motor & cables in high-voltage power system should always be in good condition, so testing&monitoring insulation of all parts in system is necessary. ZJC high voltage online insulation system can test and monitor the insulation value of all the devices and cables at any time,once it finds the insulation value declining to presetting warning value it will send the signal for alarm or to stop the motor to prevent occurrence of accidents.


3. Monitoring online the power system’s safety condition!

According to the new technologies checking, at present in the world there is no such an instrument could be used to isolate the AC high voltage system and energize the DC 1500V directly on the AC system to test its insulation value.ZJC high voltage insulation online monitoring system could resolve this problem perfectly , which use RS-485 port to connect to the computer control room to test and monitor the insulation value at any time, achieved the closed loop control in a real sense.


Applications

ZJC high voltage insulation online monitoring system is a special instrument for testing and monitoring insulation resistance to earth of high voltage power system, it can be used to the following places:

1. High voltage motor insulation monitoring on line: 500kW----40000kW.

2. Power system insulation monitoring on line: 3kV,6kV,10kV,35kV high voltage power system.


Main Function

The products have the following8 main functions:

1. Measuring insulation resistance

This series of products can be used to measure insulation resistance. Measurement principle: for measuring insulation on line, we use “dc superposition method”, just as Meg Ohm Meter, it is that: being connected to 220V AC power, it will generate 1500V DC, this DC power will be added on the measured system, and formed a circle loop circuit between the object being measured and the earth and could be used to test the insulation for high voltage power system. 


2. Measuring Polarization Index

In process of measuring insulation resistance, a certain time insulation value for insulativity is incomplete (or a certain time insulation value can not stand for the insulativity is good or bad );so it needs us to measure the polarization index of the insulation( the ratio of 10min insulation value and 1 min insulation value).In reality, measurement like this no doubt will add a lot of work, especially for lots of motors. Our instrument has the function of measuring of polarization index, this function could greatly reduce the labor intensity for maintenance person, improves the convenience of measuring.


3. Measuring absorptance

As the same as Polarization Index, the insulativity still need another parameter: the absorptance to identify whether the insulativity is good or not. Absorptance is the ratio between insulation value get at 60s and the 15s, because of the time of DC volt load up to measured object is different, and also the environment factor and other factors effects, compare the ratio of this two time can identify the insulativity is good or bad. Our instrument has the function of measuring the absorptance, It will help you to know the absorptance easily.


4. Measuring leakage current

Another important parameter for insulation is the leakage current. Our instrument has specially measuring system, take the high sensitive leakage current detecting ring to measuring the system or motor’s three phase unbalance current. .Normally, these three phases are balanced, when one or two phases became weaken, it will unbalance and combine the insulation value we will know the insulation level of the system or motor.


5. SMS alarm(short message alarm)

Our instrument has the function of SMS alarm, when the insulation monitoring system detect the insulation weakened, comparing the setting value, if the measured value lower or surpass the presetting valve, it will send warning or alarming message to safety person to avoid the accidents happen suddenly.


6. Remote setting of monitoring object

Our instrument has a upper-computer software, which has convenient and simple operation interface, benefit to the measuring personnel to sit in the office to measure the insulation level as they need at any time, improved the working condition and efficiency.


7. Setting measured time interval freely

The best is we know the insulativity of system or motor at any where/time to make sure the system or motor is operation safe; for traditional instruments to test and monitor the insulation value there exists many problems, such as they cannot measure the insulation value online or under high voltage electric, or keep load up the high volt to the measure object and made the system or motor in extra risk. Now our instrument can achieved that setting measured time freely and you can measure the insulation value at any time you want, reduce the risk of long time load up volt to system or motor, it is the best solution for the insulation problems now.


8. Measuring On-line& off-line

For user’s requirements of on-line or off-line measuring, this instrument perform well, this greatly improves the convenience for operation and maintenance person.



Oil Evacuation and Nitrogen Injection Extinguishing Equipment for Oil-immersed Transformer



Oil Evacuation and Nitrogen Injection Extinguishing Equipment for Oil-immersed Transformer



Oil Evacuation and Nitrogen Injection Extinguishing Equipment for Oil-immersed Transformer


Transformer Explosion and Fire Prevention system
         Oil-immersed Tra...
  • QQ

  • WeChat

  • Telephone

    86-10-52421389
  • Email

Please select customer service to chat

  • WeChat

    Long press to identify the QR code
Click on the phone to make a call
Click on the mailbox to send a key